Common vent systems are prohibited.
													
																	Minimum gas appliance vent clearance from roof. 
									
	
		
	
																	Venting systems vent connectors slope in ft upward to chimney vent not smaller than appliance flue up to 2 sizes larger than appliance flue length depends on type for single appliance single wall 75 of vent height b vent 100 of vent height 18 inch diameter for multiple appliances 34. 
																	Stack vents may give off sewer gas so they should not be located within 3 feet of an operable window. 
																	Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air. 
																	The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch 25 mm. 
															
													
									
	
		
	
																	3 chimney vent caps larger than 12 must be located at least 2 feet above the highest point and 2 feet higher than any portion of the building within a horizontal distance of 10 feet. 
																	Number 2 is a vent for an exhaust fan like those found in bathrooms and laundry rooms. 
																	Appliances designed for natural draft venting and incorporating integral venting means shall be located so that a minimum clearance of 9 inches 229 mm is maintained between vent terminals and from any openings through which combustion products enter the building. 
																	They exhaust moist air to the outside.